Applications – Single-acting cylinders. Actuation – Lever operated.
Functions – Cylinder piston “advance,” “hold” and “return."
Used on these pumps – P460, PE17, PE21, PE30, PE46, PE55, PE84, PE90 and PE120 series.
NOTE: A Pressure Switch and/or Gauge (Analog or Digital) may be attached to this valve.
CAUTION: To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.
IMPORTANT: Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.
IMPORTANT: When ordering any valve for a PE30 or PG30 series pump, ½” longer mounting screws are required. For valves 9504, 9584, 9610 and 9610A, order four 12001 cap screws. For valve 9582, order two 12001 and two 10856 cap screws.