CHOOSE YOUR BASIC PUMP, SELECT YOUR ACCESSORIES, AND WE WILL ASSEMBLE, TEST AND SHIP YOUR PUMP.
ORDER A “CUSTOM BUILT” HYDRAULIC PUMP“Assemble to Order” means you can choose a basic pump with gas, air or electric motor. Then select the proper valve, gauge, pressure control, motor control and reservoir. You get a two-stage pump that gives high oil volume for fast cylinder approach (and return with double- acting cylinders) in the first stage and high pressure in the second stage.
1.) 1 1/8 HP UNIVERSAL MOTORThese motors start under full load and are suitable for operation up to 5,000 or 10,000 psi. The motor is 11⁄8 hp, 12,000 rpm, 115 or 230 volt (specify), 50/60 cycle A.C. single phase (25 amp draw at 115V.). With proper valve they can be used with single- or double-acting cylinders. Remote control available.
2.) 1 1/2 HP JET MOTOR, SINGLE & THREE-PHASEFeature low noise level, moderate speed for long service and are ideal for fixed applications. Motor is 11⁄2 hp, 3,450 rpm, 115 or 230 volt, 50 or 60 cycle (specify), A.C. single phase with thermal overload switch. Can be used with single- or double-acting cylinders and equipped with remote control. Also available in 230/460 volt, three-phase (specify).
NOTE: These do not start under full load unless valve is in “neutral” (requires open or tandem center valve) and are not recommended for frequent starting and stopping.
3.) 3 HP JET MOTOR, THREE-PHASEGives low noise level and long life due to its moderate operating speed. Ideal for fixed installations. Consists of basic 10,000 psi pump, jet pump motor: 3 hp, 3,450 rpm, 230/460 volt, 60 or 50 cycle (specify). A.C. threephase, with thermal overload switch. Equipped with internal and external relief valve. Will start under load.
4.) 3 HP AIR MOTORThis pump is ideal for use where electricity is unavailable or cannot be used. The 5,000 or 10,000 psi pump has a 3 hp air driven motor at 3,000 rpm (optimum performance based on 80 psi air pressure and 50 cfm at the pump). You can drive single- or double- acting cylinders with the correct valve.
NOTE: 80 psi air supply required to start under full load.
5.) GASOLINE ENGINEThis version is perfect when electricity and air are unavailable. It is capable of continuous operation at full pressure. Consists of basic 10,000 psi pump, 4-cycle Briggs & Stratton “Diamond Edge” gasoline engine, developing 6 hp. As with all these pumps, this unit can be valved for use with either single- or doubleacting cylinders.
"ASSEMBLE TO ORDER" PUMPHOW TO ORDER YOUR "CUSTOM" HYDRAULIC PUMP..."You can choose from pre-engineered, off-the-shelf components to customized your pump. All the components are listed in table form, with key letters or numbers in 'Specifications'. Complete instructions guide you so you can determine what is needed to complete a pump assembly. Shown below is an example of a custom-built pump.


Pump No. PE55A-VV-Z-G-A-A-A-A-D-BB-C-2F is a 10,000 psi two-speed pump with a 115 volt, 50-60Hz, single phase, 1 1/2 hp, 12,000 rpm motor; a 9512 4-way solenoid valve with a 202778 remote hand control, a 9041 pressure gauge, no gauge accessories, standard pressure control, standard On-Off-Pulse motor control, 400630OR9 2-gallon reservoir, a 350431 fluid level/temperature gauge, 10494 casters, and 2 gallons of standard hydraulic oil.
TO BUILD YOUR PUMP, FILL IN KEY LETTERS FROM CHARTS
| 1. Basic Pump | 2. Select Valve | 3. Select Valve Control | 4. Select Gauge | 5. Select Gauge Accessories | 6. Pressure Control |
|---|
|
|
|
|
|
|
| 7. Pressure Switch | 8. Motor Control | 9. Reservoir | 10. Level/Temp Gauge | 11. Choose Casters | 12. Select Oil |
|---|
|
|
|
|
|
|
Use the charts numered from 1-12 below to select the pump, valve, gauge and other accessories to suit your needs. For the pump, fill in the basic number plus key letter in block 1 above and the key letter only in the blocks 2-12 above for any of the other items. Refer to the appropriate web pages for more specific information on the products you need.
1. BASIC PUMP| Basic Pump Numbers | Specifications
Note: Customer must specify voltage required. |
|---|
PE55
(10,000 psi) | PE90
(5,000 psi) | PE120
(10,000 psi) | PA55
(5,000 psi) | PA90
(5,000 psi) | PG55
(10,000 psi) | Power Source | rpm | hp |
|---|
| A or AC* | A or AC* |
|
|
|
| 115V-60 Hz, 1Ø | 12,000 | 1 1/8 |
|
|
|
|
|
| 110V-50 Hz, 1Ø | 12,000 | 1 1/8 |
| B or BC* | B or BC* |
|
|
|
| 230V-60 Hz, 1Ø | 12,000 | 1 1/8 |
|
|
|
|
|
| 220V-50 Hz, 1Ø | 12,000 | 1 1/8 |
| † C or CC* | † C or CC* |
|
|
|
| 115V-60 Hz, 1Ø | 3,450 | 1 1/2 |
| † C50 | † C50 |
|
|
|
| 110V-50 Hz, 1Ø | 2,850 | 1 1/2 |
| † D or DC* | † D or DC* |
|
|
|
| 230V-60 Hz, 1Ø | 3,450 | 1 1/2 |
| † D50 | † D50 |
|
|
|
| 220V-50 Hz, 1Ø | 2,850 | 1 1/2 |
| † F60 ** | † F60 ** |
|
|
|
| 208, 230/460V-60 Hz, 3Ø | 3,450 | 1 1/2 |
| † F50 ** | † F50 ** |
|
|
|
| 220/380V-50 Hz, 3Ø | 2,850 | 1 1/2 |
|
| M60 ** |
|
|
| 208, 230/460V-60 Hz, 3Ø | 3,450 | 3 |
|
| M50 ** |
|
|
| 220/380V-50 Hz, 3Ø | 2,850 | 3 |
|
|
| A | A |
| Air Motor | 3,000 | 3 |
|
|
|
|
| A | Gas Engine | 3,600 | 6 |
*Suffixes AC, BC, CC & DC indicate pumps for Canadian orders only.
NOTE: All electric units have 24 volt secondary circuit.
**Specify voltage required.
† These pumps do not start under full load unless valve is in “neutral” position (requires open or tandem center valve) and are not recommended for frequent starting and stopping. |
2. VALVE| Manifold/Manual/Air Operated Directional Valves | Function | Manifold/Manual/Air Operated Directional Valves | Function |
|---|
| AB | 9628 manual, tandem center | 4-way, 3 pos.valves | O | 9609 manual, pressure compensated flow control | 3-way, 4 pos. |
| AC | 9632 manual "twin" tandem and open center | R | 9506 manual, tandem center "Posi-Check*" | 4-way, 3 pos. valves |
| A | None | — | RR | 9511 manual, open center |
| B | 9626 manifold | Manifold 3-way, 2 pos. valves | S | 9500 manual, tandem center |
| C | 9584 manual | T | 9507 manual, closed center "Posi-Check*" |
| D | 9582 manual | U | 9501 manual, closed center | |
| E | 9610 automatic, pilot operated | FF | 9569 solenoid operated -24 volt | 3-way, 2 pos. |
| G | 9504 manual | 3/4-way, 2 pos. valves | Solenoid Operated Directional Valves | Function |
|---|
| JJ | 9594 air operated | HH | 9572 solenoid operated -24 volt | 3/4-way, 2 pos. |
| L | 9502 manual, closed center "non-interflow" | 3-way, 3 pos. valves | PP | 9599 solenoid operated -24 volt | 3-way, 3 pos. |
| M | 9520 manual, tandem center "Posi-Check*" | VV | 9512 solenoid operated -24 volt | 4-way, 3 pos. valves |
| N | 9576 manual, metering tandem center | | WW | 9615 solenoid operated -24 volt |
3. VALVE CONTROL| Valve Remote Control | Use with Valve | Valve Remote Control | Use with Valve |
|---|
| A | None | – | Z | 202778 remote hand control, 10 ft. | 9512 or 9615 |
| X | 304718 remote hand control, 10 ft. | 9572 | ZF | 309653 remote foot control, 10 ft. | 9512, 9615, 9569 or 9599 |
| XF | 309652 remote foot control, 10 ft. | 9572 | ZZ | 209593 remote hand control, 12 ft. | 9594 |
| Y | 202777 remote hand control, 10 ft. | 9569 or 9599 | | | |
4. PRESSURE GAUGE| Pressure Gauges |
|---|
| A | None |
| B | Other – Specify. |
| G | 9041 0-10,000 psi – 0-689 Bar (2 1⁄2" dia.) |
| H | 9040 0-10,000 psi – 0-689 Bar (Liquid) (2 1⁄2" dia.) |
| J | 9051 0-10,000 psi – 0-689 Bar (4" dia.) |
| M | 9052 0-10,000 psi – 0-689 Bar (Liquid) (4" dia.) |
5. GAUGE ACCESSORIES| Gauge Accessories |
|---|
| A | None |
| N | 9049 pulsation dampener – All dry gauges |
6. PRESSURE CONTROL| Pressure Control |
|---|
| A | With standard external pressure regulator |
| C | Other – specify |
| D | 350199 premium external pressure regulator.
See Power Team Catalog product No. 9633 for details. |
7. PRESSURE SWITCH| Pressure Switch |
|---|
| A | None |
| B | 9625 electric pressure switch (500-10,000 psi)
NOTE: Pressure switch is factory pre-set at 10,000 psi
unless otherwise specified. |
| C | 9641 pilot operated air control valve – N.C. |
| D | 9643 pilot operated air control valve – N.O. |
8. MOTOR CONTROL| Electric Motor Controls |
|---|
| A | Standard On/Off/Pulse control (does not include remote switch) for A, B, C, D, F and M electric pumps. Also used for remote controlled solenoid valves. |
| B | None |
| C | 25017 remote motor hand switch, 10 ft.
|
| D | 203225 remote motor hand switch, 10 ft. |
| E | 10461 remote motor foot switch, 10 ft. |
| Air Motor Controls |
|---|
| AA | Other |
| B | None |
| P | 27876 hand motor control (for PA55 & PA90 series)
|
| Q | 27877 foot motor control (for PA55 & PA90 series) |
9. RESERVOIRS| Reservoirs | Capacity |
|---|
| A | None | – |
| B | Other – Specify | – |
| D | 40063OR9 – PE55, PE90, PE120, PA55 and PA90 series
| 2 1/2 gal. |
| E | 61165† – PE55, PE90, PE120, PA55 and PA90 series | 2 gal. |
| | (Oil temperatures in excess of 150° F. may cause permanent failure of the thermoplastic reservoir) | |
| F | RP22† - PE55, PE90, PE120, PA55 and PA90 series | 2 1/2 gal. |
| H | 61799OR9
Same as D except with drain port | 2 1/2 gal. |
| J | RP50 – PE55, PE90, PE12, PA55 and PA series | 5 gal. |
| K | 40137OR9 – PG55 series | 5 gal. |
| P | 209124 – PE55, PE90, PE120, PA55 and PA90 series | 7 gal. |
| V | RP100 – PE55, PE90, PE120, PA55 and PA90 series | 10 gal. |
| W | RP101 – PG55 series | 10 gal. |
NOTE: Includes cover adapter and misc. accessories when applicable.
†High density polyethylene.
‡Aluminum. |
10. FLUID LEVEL/TEMPERATURE GAUGE| Fluid Level/Temperature Gauge |
|---|
| A | None |
| BB | 350431 fluid level/temperature gauge |
11. CASTERS| Casters |
|---|
| A | None |
| C | 10494 caster for use with 40063OR9 reservoir
(Specify quantity of four) |
12. OIL| Oil |
|---|
| E | Ship pump without oil |
| F | 9637 1 gal. standard hydraulic oil |
| G | 9638 2 1⁄2 gal. standard hydraulic oil
|
| Q | 9639 1 gal. Flame-Out hydraulic oil |
| R | 9640 2 1⁄2 gal. Flame-Out hydraulic oil |
| U | 9645 1 gal. biodegradable hydraulic oil |
| V | 9646 2 1⁄2 gal. biodegradable hydraulic oil |
| NOTE: Select type of hydraulic oil and specify quantity. |
Go to Accessories section for product detail:
Hydraulic Pump Accessories:On/Off Motor Control, Remote Air Motor Controls, Subplates, Pump Mounted Subplates, Air Filter/Regulator/Lubricator, Pressure Switch, Pilot Operated Air Control Valves, Foot Control Guard, and Magnetic Strip.
On/Off Motor Control:| Order No. | Description | Weight
(lbs.) |
|---|
| 25017 | Remote hand control. Has a push button switch, with a 10 foot cord. | 0.8 lb |
| 203225 | Remote hand control. Heavy-duty with single push button switch in a neoprene housing with 10 foot cord. Housing seals out dust, lint and liquids (unit is not submersible). | 0.8 lb. |
| 10461 | Remote foot control, with 10 foot cord. | 3 lbs. |
| 251660 | Remote foot control, with 10 foot cord. For use with the PE10 style pumps. | 1 lb. |
Remote Air Motor Controls:| Order No. | Description | Weight
(lbs.) |
|---|
| 209593 | Remote hand control with 12 foot cord. | 2 lbs. |
| This remote hand control has two momentary push buttons, one for advance and one for retract with spring offset to hold. To be used with 4-way/2-position air pilot valves. |
Subplates| Order No. | Description | Weight
(lbs.) |
|---|
| 9510 | Subplate for remote mounting the following valves; 9500, 9501, 9502, 9504, 9506, 9507, 9511, 9552, 9572, 9575, 9576, 9592, 9594 and 9609. | 1.5 lbs.. |
| 9620 | For use with 9500, 9501, 9502, 9552, 9572, 9592 and 9594. Same as No. 9510 but has integral pressure regulating valve. | 3.8 lbs.. |
Pump-Mounted Subplates| Order No. | Description | Weight
(lbs.) |
|---|
| 9515 | Subplate | 1.3 lbs. |
| 9521 | Subplate for use under most pump mounted valves to provide adjustable pressure control on units not equipped with an external pressure regulator. | 3.8 lbs. |
Air Filter/Regulator/Lubricator:| Order No. | Description | Weight
(lbs.) |
|---|
| 9531 | Filter/regulator. 1/4" NPTF inlet and outlet. | 0.8 lbs.. |
Pressure Switch:| Order No. | Description | Weight
(lbs.) |
|---|
| 9625 | In-line pressure switch with 1/4" NPTF gauge port. | 1.1 lbs. |
| IMPORTANT: Electrical rating of switch is 5 amps at 250 volts max. To prevent permanent damage to switch, a control relay must be installed to handle currents or voltage exceeding these limits. Pressure switch should never be used to directly actuate the electrical motor. |
Pilot Operated Air Control Valves:| Order No. | Description | Weight
(lbs.) |
|---|
| 9641 | Pilot operated control valve, normally closed, with 1/4" NPTF male thread. | 1 lb. |
| 9643 | Same as 9641 except normally open. | 1 lb. |
Foot Control Guard:| Order No. | Description | Weight
(lbs.) |
|---|
| 16339 | Guard for use with 10461 and 251660 foot controls. | 4.5 lbs. |
Magnetic Strip:| Order No. | Description | Weight
(lbs.) |
|---|
| 207762 | Magnetic strip with adhesive back can be added to No. 25017, 202777, 202778 and 304718 hand controls. Provides 6 lbs. of holding force. | 0.1 lb. |